- Jan 07, 2018 -

The use of pneumatic diaphragm pump operation should pay attention to the following points:

1, to ensure that the maximum particles contained in the fluid does not exceed the maximum safety of the pump through the particle diameter standard.

2, the intake pressure Do not exceed the maximum allowable pressure pump, compressed air above the rated pressure may result in personal injury and property damage and damage the performance of the pump.

3, to ensure that the pump pressure piping system can withstand the highest output pressure to ensure that the drive air system clean and normal working conditions.

4. Electrostatic sparks may cause personal injury and property damage due to explosion. Use wires with enough large cross-section to properly ground the grounding screws on the pump.

5, grounding requirements in line with local laws and regulations and site requirements of some special requirements.

6, fasten the pump and the connection pipe joints to prevent electrostatic sparks due to vibration impact. Use antistatic hose.

7, to periodically check and test the reliability of the grounding system, grounding resistance requirements of less than 100 ohms.